53 lines
1.3 KiB
C
53 lines
1.3 KiB
C
/*
|
|
* Copyright © Stéphane Raimbault <stephane.raimbault@gmail.com>
|
|
*
|
|
* SPDX-License-Identifier: LGPL-2.1-or-later
|
|
*/
|
|
|
|
#ifndef MODBUS_TCP_H
|
|
#define MODBUS_TCP_H
|
|
|
|
#include "modbus.h"
|
|
|
|
MODBUS_BEGIN_DECLS
|
|
|
|
#if defined(_WIN32) && !defined(__CYGWIN__)
|
|
/* Win32 with MinGW, supplement to <errno.h> */
|
|
#include <winsock2.h>
|
|
#if !defined(ECONNRESET)
|
|
#define ECONNRESET WSAECONNRESET
|
|
#endif
|
|
#if !defined(ECONNREFUSED)
|
|
#define ECONNREFUSED WSAECONNREFUSED
|
|
#endif
|
|
#if !defined(ETIMEDOUT)
|
|
#define ETIMEDOUT WSAETIMEDOUT
|
|
#endif
|
|
#if !defined(ENOPROTOOPT)
|
|
#define ENOPROTOOPT WSAENOPROTOOPT
|
|
#endif
|
|
#if !defined(EINPROGRESS)
|
|
#define EINPROGRESS WSAEINPROGRESS
|
|
#endif
|
|
#endif
|
|
|
|
#define MODBUS_TCP_DEFAULT_PORT 502
|
|
#define MODBUS_TCP_SLAVE 0xFF
|
|
|
|
/* Modbus_Application_Protocol_V1_1b.pdf Chapter 4 Section 1 Page 5
|
|
* TCP MODBUS ADU = 253 bytes + MBAP (7 bytes) = 260 bytes
|
|
*/
|
|
#define MODBUS_TCP_MAX_ADU_LENGTH 260
|
|
|
|
MODBUS_API modbus_t *modbus_new_tcp(const char *ip_address, int port);
|
|
MODBUS_API int modbus_tcp_listen(modbus_t *ctx, int nb_connection);
|
|
MODBUS_API int modbus_tcp_accept(modbus_t *ctx, int *s);
|
|
|
|
MODBUS_API modbus_t *modbus_new_tcp_pi(const char *node, const char *service);
|
|
MODBUS_API int modbus_tcp_pi_listen(modbus_t *ctx, int nb_connection);
|
|
MODBUS_API int modbus_tcp_pi_accept(modbus_t *ctx, int *s);
|
|
|
|
MODBUS_END_DECLS
|
|
|
|